The cables are designed for use in the Electric Submersible Pump Units with rated voltage between 4kV and 5kV. The permissible working temperature ranges from90℃ to 232℃ .These cables have the excellent ability of Oil Resistance, Heat Resistance and Corrosion Resistance. Note: The rated voltage...
The cables are designed for use in the Electric Submersible Pump Units with rated voltage between 4kV and
5kV. The permissible working temperature ranges from90℃ to 232℃ .These cables have the excellent ability
of Oil Resistance, Heat Resistance and Corrosion Resistance.
Note: The rated voltage of 4kV and 5kV can also be produced based on specific customer requirements.
Shapes and features code
a Round, use “Y” to signify. Round —— Y
b Flat, be omitted.
Insulated materials code
a EPDM —— E
b Compound insulation with polyimide-F46 composite film and EPDM —— YE
Jacket (Including Inner Jacket) Material Code
a Lead (Lead alloy), use “Q” to signify. Lead (Lead alloy) —— Q
b EPDM——E
Armor sheath code
a Monel tape armor, use “M” to signify. Monel tape armor —— M
b Galvanized steel tape armor —— be omitted
c Stainless steel tape armor —— X
Type signified method
Example:
QYEEY5-3 x 20/120
Rated voltage 5kV, EPDM insulation, EPDM jacket, galvanized steel tape armor 3 x 20mm2, Max